NHXH & NHXCH – FE180 Cable Description
NHXH and NHXCH are flame retardant and corrosion resistant (FRNC) and provide insulation integrity for 180 minutes (FE180) and circuit integrity for 30 minutes or 90 minutes (E30 or E90) in the event of fire, while minimizing the corrosive effects of fire and smoke.
These cables are suitable for both indoor and outdoor applications, but are not suitable for direct burial installation or direct placement in water. Therefore, any outdoor installation of these flame-retardant and corrosion-resistant cables should provide waterproofing measures.
NHXH cables are the standard type, while NHXCH cables include copper tape and copper wire concentric conductors that serve as both shielding and neutral conductors. If you need a higher level of protection for shielded fireproof cables, NHXCH is the better choice. If the standard fire rating is sufficient, NHXH cables are already suitable.
NHXH & NHXCH – FE180 Cable Construction
EN 60332-3-24 NHXCH - FE180-E30 0.6/1kV Cable | EN 60332-3-24 NHXCH - FE180-E90 0.6/1kV Cable | EN 60332-3-24 NHXH - FE180-E30 0.6/1kV Cable | EN 60332-3-24 NHXH - FE180-E90 0.6/1kV Cable | |
---|---|---|---|---|
VOLTAGE | 0.6/1kV | |||
CONDUCTOR | Class 1 Solid Copper Class 2 Stranded Copper |
|||
INSULATION | Halogen Free, Ceramic Polymer Compound | Halogen Free Polymer | Halogen Free, Similar Ceramic Polymer | Flame Protecting Wrapping Halogen Free Polymer |
INNER SHEATH | Halogen Free Compound | |||
CONCENTRIC CONDUCTOR | Copper Wires with Counter Helix of Copper Tape | - | ||
OUTER SHEATH | Halogen Free Polymer |
NHXH & NHXCH – FE180 Cable Characteristics
EN 60332-3-24 NHXCH - FE180-E30 0.6/1kV Cable | EN 60332-3-24 NHXCH - FE180-E90 0.6/1kV Cable | EN 60332-3-24 NHXH - FE180-E30 0.6/1kV Cable | EN 60332-3-24 NHXH - FE180-E90 0.6/1kV Cable | |
---|---|---|---|---|
Voltage Rating Uo/U | 0.6/1kV | |||
Temperature Rating | -5°C to +90°C | |||
Minimum Bending Radius | 12 x overall diameter | RE: 12 x overall diameter RM: 15 x overall diameter |
NHXH & NHXCH – FE180 Cable Applications
- Emergency Systems
- These cables are crucial for maintaining the functionality of emergency systems like fire alarms, smoke detectors, emergency lighting, and evacuation elevators.
- Life Safety
- They are used to ensure the continued operation of systems that support life-saving efforts during a fire.
- Public Buildings
- They are commonly found in public buildings like hospitals, schools, and shopping centers, where fire safety is a priority.
- EN 60332-3-24 NHXCH - FE180-E30 0.6/1kV Cable
- EN 60332-3-24 NHXCH - FE180-E90 0.6/1kV Cable
- EN 60332-3-24 NHXH - FE180-E30 0.6/1kV Cable
- EN 60332-3-24 NHXH - FE180-E90 0.6/1kV Cable
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | CONCENTRIC CONDUCTOR mm | CONDUCTOR TYPE | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
---|---|---|---|---|---|
2 | 1.5 | RE | 1.5 | 10.8 | 133 |
2 | 2.5 | RE | 2.5 | 12 | 171 |
3 | 1.5 | RE | 1.5 | 11.2 | 166 |
3 | 2.5 | RE | 2.5 | 12.5 | 219 |
3 | 4 | RE | 4 | 13.4 | 291 |
3 | 6 | RE | 6 | 15.3 | 393 |
3 | 10 | RE | 10 | 17 | 576 |
3 | 16 | RE | 16 | 19.6 | 860 |
3 | 25 | RM | 16 | 23 | 1194 |
3 | 35 | RM | 16 | 25.6 | 1521 |
3 | 50 | RM | 25 | 28.8 | 2037 |
3 | 70 | RM | 35 | 33.7 | 2841 |
3 | 95 | RM | 50 | 38.2 | 384 |
3 | 120 | RM | 70 | 42.3 | 4869 |
3 | 150 | RM | 70 | 46.6 | 5844 |
3 | 185 | RM | 95 | 52.3 | 7400 |
3 | 240 | RM | 120 | 59.7 | 9661 |
4 | 1.5 | RE | 1.5 | 11.9 | 192 |
4 | 2.5 | RE | 2.5 | 13.3 | 254 |
4 | 4 | RE | 4 | 14.3 | 341 |
4 | 6 | RE | 6 | 16.3 | 471 |
4 | 10 | RE | 10 | 18.2 | 685 |
4 | 16 | RM | 16 | 21.1 | 1035 |
4 | 25 | RM | 16 | 25 | 1465 |
4 | 35 | RM | 16 | 27.8 | 1886 |
4 | 50 | RM | 25 | 31.6 | 2539 |
4 | 70 | RM | 35 | 37 | 3556 |
4 | 95 | RM | 50 | 41.9 | 4816 |
4 | 120 | RM | 70 | 46.6 | 6101 |
4 | 150 | RM | 70 | 51.1 | 7323 |
4 | 185 | RM | 95 | 57.6 | 9285 |
4 | 240 | RM | 120 | 65.8 | 12141 |
5 | 2.5 | RE | 2.5 | 14.3 | 283 |
5 | 6 | RE | 6 | 17.5 | 530 |
7 | 1.5 | RE | 2.5 | 14.2 | 274 |
12 | 1.5 | RE | 2.5 | 17.4 | 399 |
24 | 1.5 | RE | 6 | 23.7 | 744 |
30 | 1.5 | RE | 6 | 24.8 | 873 |
7 | 2.5 | RE | 2.5 | 15.4 | 348 |
12 | 2.5 | RE | 4 | 19.2 | 556 |
24 | 2.5 | RE | 10 | 26.1 | 1027 |
30 | 2.5 | RE | 10 | 27.4 | 1216 |
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | CONDUCTOR TYPE | CONCENTRIC CONDUCTOR mm | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
---|---|---|---|---|---|
2 | 1.5 | RE | 1.5 | 16 | 300 |
2 | 2.5 | RE | 2.5 | 17 | 350 |
3 | 1.5 | RE | 1.5 | 16.8 | 363 |
3 | 2.5 | RE | 2.5 | 17.9 | 434 |
3 | 4 | RE | 4 | 19 | 434 |
3 | 6 | RE | 6 | 21 | 434 |
3 | 10 | RE | 10 | 24.1 | 949 |
3 | 16 | RE | 16 | 27.3 | 1340 |
3 | 25 | RM | 16 | 30.7 | 1766 |
3 | 35 | RM | 16 | 33.3 | 2172 |
3 | 50 | RM | 25 | 37.4 | 2857 |
3 | 70 | RM | 35 | 42.5 | 3839 |
3 | 95 | RM | 50 | 47.8 | 5082 |
3 | 120 | RM | 70 | 51.4 | 6204 |
3 | 150 | RM | 70 | 55.7 | 7340 |
3 | 185 | RM | 95 | 61.7 | 9142 |
3 | 240 | RM | 120 | 67.9 | 11582 |
4 | 1.5 | RE | 1.5 | 18 | 450 |
4 | 2.5 | RE | 2.5 | 19.2 | 505 |
4 | 4 | RE | 4 | 20.3 | 608 |
4 | 6 | RE | 6 | 22.5 | 777 |
4 | 10 | RE | 10 | 26.4 | 1153 |
4 | 16 | RM | 16 | 29.3 | 1584 |
4 | 25 | RM | 16 | 33.1 | 2120 |
4 | 35 | RM | 16 | 36 | 2634 |
4 | 50 | RM | 25 | 41.1 | 3524 |
4 | 70 | RM | 35 | 46.2 | 4695 |
4 | 95 | RM | 50 | 52 | 6242 |
4 | 120 | RM | 70 | 56 | 7622 |
4 | 150 | RM | 70 | 61 | 9096 |
4 | 185 | RM | 95 | 67.5 | 11307 |
4 | 240 | RM | 120 | 74.4 | 14359 |
7 | 1.5 | RE | 2.5 | 20.9 | 588 |
7 | 2.5 | RE | 2.5 | 22.1 | 696 |
12 | 1.5 | RE | 2.5 | 26.2 | 620 |
12 | 2.5 | RE | 2.5 | 28.2 | 1168 |
24 | 1.5 | RE | 6 | 37.6 | 1979 |
24 | 2.5 | RE | 2.5 | 41 | 2465 |
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | CONDUCTOR TYPE | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
---|---|---|---|---|
1 | 16 | RM | 18.6 | 207 |
1 | 25 | RM | 20.6 | 307 |
1 | 35 | RM | 22.8 | 407 |
1 | 50 | RM | 26.3 | 535 |
1 | 70 | RM | 30 | 744 |
1 | 95 | RM | 10.2 | 1009 |
1 | 120 | RM | 18.6 | 1248 |
1 | 150 | RM | 20.6 | 1538 |
1 | 185 | RM | 22.8 | 1917 |
1 | 240 | RM | 26.3 | 2521 |
1 | 300 | RM | 30 | 3400 |
2 | 1.5 | RE | 10.2 | 145 |
2 | 2.5 | RE | 11 | 180 |
2 | 4 | RE | 11.8 | 224 |
2 | 6 | RE | 12.8 | 282 |
2 | 10 | RE | 14.4 | 393 |
2 | 16 | RM | 17.3 | 605 |
3 | 1.5 | RM | 10.6 | 165 |
3 | 2.5 | RM | 11.5 | 209 |
3 | 4 | RM | 12.4 | 268 |
3 | 6 | RM | 13.5 | 344 |
3 | 10 | RM | 15.6 | 506 |
3 | 16 | RM | 18 | 761 |
3 | 25 | RM | 22.3 | 1160 |
3 | 35 | RM | 24.9 | 1522 |
3 | 50 | RM | 27.7 | 198 |
3 | 70 | RM | 32 | 2746 |
3 | 95 | RM | 36.5 | 3712 |
3 | 25/16 | RM | 23.4 | 1335 |
3 | 35/16 | RM | 25.7 | 1683 |
3 | 50/25 | RM | 29 | 2244 |
3 | 70/35 | RM | 33.4 | 3101 |
3 | 95/50 | RM | 38.3 | 4207 |
3 | 120/70 | RM | 42.6 | 5315 |
4 | 1.5 | RE | 11.3 | 192 |
4 | 2.5 | RE | 12.3 | 249 |
4 | 4 | RE | 13.3 | 322 |
4 | 6 | RE | 14.5 | 418 |
4 | 10 | RE | 16.8 | 620 |
4 | 16 | RM | 19.8 | 944 |
4 | 25 | RM | 24.3 | 1452 |
4 | 35 | RM | 27.1 | 1906 |
4 | 50 | RM | 30.5 | 2514 |
4 | 70 | RM | 35.3 | 3497 |
4 | 95 | RM | 40.2 | 4728 |
4 | 120 | RM | 44.5 | 5882 |
4 | 150 | RM | 49 | 7199 |
5 | 1.5 | RE | 12.2 | 228 |
5 | 2.5 | RE | 13.3 | 295 |
5 | 4 | RE | 14.4 | 386 |
5 | 6 | RE | 16.1 | 518 |
5 | 10 | RE | 18.3 | 755 |
5 | 16 | RM | 22.2 | 1187 |
5 | 25 | RM | 26.6 | 1773 |
5 | 35 | RM | 29.8 | 2341 |
5 | 50 | RM | 33.7 | 3100 |
7 | 1.5 | RE | 13 | 274 |
10 | 1.5 | RE | 16.4 | 397 |
12 | 1.5 | RE | 16.8 | 438 |
19 | 1.5 | RE | 19.2 | 606 |
24 | 1.5 | RE | 22.6 | 785 |
30 | 1.5 | RE | 23.7 | 917 |
7 | 2.5 | RE | 14.2 | 358 |
12 | 2.5 | RE | 18 | 580 |
19 | 2.5 | RE | 21.8 | 852 |
24 | 2.5 | RE | 25 | 1054 |
30 | 2.5 | RE | 26.3 | 1245 |
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | CONDUCTOR TYPE | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
---|---|---|---|---|
1 | 16 | RM | 10.5 | 250 |
1 | 25 | RM | 12.5 | 355 |
1 | 35 | RM | 13.5 | 460 |
1 | 50 | RM | 15 | 596 |
1 | 70 | RM | 16.5 | 810 |
1 | 95 | RM | 19 | 1100 |
1 | 120 | RM | 20.5 | 1350 |
1 | 150 | RM | 22.5 | 1650 |
1 | 185 | RM | 25 | 2050 |
1 | 240 | RM | 28 | 2650 |
1 | 300 | RM | 31 | 3275 |
2 | 1.5 | RE | 14.3 | 275 |
2 | 2.5 | RE | 14.9 | 320 |
3 | 1.5 | RE | 15 | 315 |
3 | 2.5 | RE | 15.9 | 371 |
3 | 4 | RE | 16.7 | 435 |
3 | 6 | RE | 17.8 | 526 |
3 | 10 | RE | 19.5 | 691 |
3 | 16 | RM | 22.3 | 982 |
3 | 25 | RM | 25.8 | 1392 |
3 | 35 | RM | 28.4 | 1778 |
3 | 35/16 | RM | 29.5 | 1964 |
3 | 50/25 | RM | 33.6 | 2633 |
3 | 70/35 | RM | 38.1 | 3563 |
3 | 95/50 | RM | 43.4 | 4768 |
3 | 120/70 | RM | 46.9 | 5856 |
4 | 1.5 | RE | 16.1 | 365 |
4 | 2.5 | RE | 17 | 429 |
4 | 4 | RE | 18 | 515 |
4 | 6 | RE | 19.2 | 628 |
4 | 10 | RE | 21.1 | 839 |
4 | 16 | RE | 24.3 | 1210 |
4 | 25 | RM | 28.1 | 1717 |
4 | 35 | RM | 31 | 2209 |
4 | 50 | RM | 35.1 | 2921 |
4 | 70 | RM | 40 | 3980 |
4 | 95 | RM | 45.2 | 5321 |
4 | 120 | RM | 49 | 6475 |
4 | 150 | RM | 53 | 7725 |
5 | 1.5 | RE | 17.4 | 429 |
5 | 2.5 | RE | 18.4 | 506 |
5 | 4 | RE | 19.5 | 612 |
5 | 6 | RE | 20.9 | 752 |
5 | 10 | RE | 23 | 1009 |
5 | 16 | RM | 26.6 | 1465 |
5 | 25 | RM | 30.9 | 2105 |
5 | 35 | RM | 36 | 2500 |
7 | 1.5 | RE | 18.6 | 497 |
7 | 2.5 | RE | 19.8 | 599 |
12 | 1.5 | RE | 23.5 | 744 |
12 | 2.5 | RE | 25.2 | 910 |
Why Huadong Cable
Our vision is to become an internationally renowned brand in the field of cables; customer satisfaction, employee promotion, and corporate development are our service tenets; high standards, globalization, and building an international brand are our business philosophy.
About HuaDong
Henan Huadong Cable Co., Ltd. was founded in 1999 which is a joint-stock national high-tech enterprise integrating scientific research, industry and trade. Huadong Cable is deeply integrated into the "Belt and Road" construction and exports to more than 130 countries around the world, including Europe, South America, North America, the Middle East, Africa, Asia, and Oceania.
HuaDong Technology
Huadong Cable focuses on technology research and development which has 60 professional personnel with senior professional titles, and has more than 100 invention and utility model patents. Huadong has a team of experienced technical engineers to ensure the quality of cables.
Main Products
Our main products : marine cables, power cables, overhead cables, fireproof cables, low-smoke halogen-free cables, rubber cables, high temperature resistant cables, instrument and control cables, solar cables and other products.
ISO, SGS, BV CERTIFICATION; TECHNICAL PATENTS AND PRODUCT CERTIFICATION
TECHNICAL AND CLIENTS
Export Countries
Technical Patents
Annual Productivity
Employees