400Hz Airport Cable Description
These cables typically feature stranded copper conductors, XLPE or EPR insulation, and a polyurethane (PUR) outer sheath, offering oil, UV, and weather resistance. They are usually bright yellow for safety.
Primarily used when aircraft are parked on the airport tarmac with engines off, they provide a grounding power connection to facilitate pre-flight preparation, inspections, and maintenance.
400Hz Airport Cable Construction
| 400Hz Single Core Airfield Cable | 400Hz Single Core Airfield Grounding Cable | 400Hz Single Core with Control Wires | 400Hz 3 core with Control Wires | 400Hz 4 core with Control Wires | |
|---|---|---|---|---|---|
| Conductor | Class 5 Stranded copper conductor | Class 6 Stranded copper conductor | Class 5/Class 6 Stranded copper conductor | ||
| Insulation | TPE (thermoplastic elastomer) | XLEPR (Cross-linked Ethylene Propylene Rubber) | TPE (Thermoplastic Elastomer) | XLEPR (Cross-linked Ethylene Propylene Rubber) | |
| Control Core | - | Stranded Copper conductor with TPE insulation | Stranded Copper conductor with XLPE insulation | Stranded copper conductor with polyolefin insulation | |
| Screen | - | Concentric Copper Wires | - | ||
| Outer Sheath | - | PUR (Polyurethane) | PUR (Polyurethane) with abrasion indicators | PUR (Polyurethane) | |
| 400Hz 7 core Airfield Cable | 400Hz 7 core with Control Wires and Reinforcement | 400Hz 7 core with Copper Tape Shield | 400Hz 7 core LSZH AWA Airfield Cable | 400Hz 7 core with Copper Wire Braid Shield | |
|---|---|---|---|---|---|
| Conductor | Class 2/Class 5 Stranded bare copper conductor | Class 5/Class 6 Stranded bare copper | Class 5 Stranded bare copper | Class 2 Stranded bare copper conductor | Class 2/Class 5 Stranded bare copper |
| Insulation | PVC (Polyvinyl Chloride) or XLPE (Cross-linked Polyethylene) | EPR (Ethylene propylene rubber) | XLPE (Cross linked Polyethylene) | ||
| Control Core | - | Stranded copper conductor with EFTE (Ethylene Tetrafluorethylene) insulation | - | ||
| Tape | - | Wrapping | - | ||
| Inner Sheath | - | PO (Polyolefin) | LSZH (Low smoke zero halogen) | - | |
| Screen | - | Copper tape | - | Copper Wire Braid | |
| Armour | - | AWA (Aluminium wire armour) | - | ||
| Outer Sheath | PVC (Polyvinyl Chloride) | PUR (Polyurethane) with integrated open meshed braid | PO (Polyolefin) | LSZH (Low smoke zero halogen) | PVC (Polyvinyl chloride) |
400Hz Airport Cable Characteristics
| 400Hz Single Core Airfield Cable | 400Hz Single Core Airfield Grounding Cable | 400Hz Single Core with Control Wires | 400Hz 3 core with Control Wires | 400Hz 4 core with Control Wires | |
|---|---|---|---|---|---|
| Rated Voltage | 0.6/1kV | ||||
| Temperature Rating | Fixed: -40°C to +90°C | ||||
| Minimum Bending Radius | Static: 6x Overall Diameter Dynamic: 7x Overall Diameter | Static: 6x Overall Diameter Dynamic: 9x Overall Diameter | Static: 6x Overall Diameter Dynamic: 7x Overall Diameter | Static: 3x Overall Diameter Dynamic: 4x Overall Diameter | Static: 4x Overall Diameter Dynamic: 5x Overall Diameter |
| 400Hz 7 core Airfield Cable | 400Hz 7 core with Control Wires and Reinforcement | 400Hz 7 core with Copper Tape Shield | 400Hz 7 core LSZH AWA Airfield Cable | 400Hz 7 core with Copper Wire Braid Shield | |
|---|---|---|---|---|---|
| Rated Voltage | 0.6/1kV | ||||
| Temperature Rating | Fixed: -20°C to +70°C | ||||
| Minimum Bending Radius | Static: 6x Overall Diameter Dynamic: 12x Overall Diameter | Static: 4x Overall Diameter Dynamic: 6x Overall Diameter | Static: 9x Overall Diameter Dynamic: 12x Overall Diameter | Static: 6x Overall Diameter Dynamic: 12x Overall Diameter |
|
- 400Hz Single Core Airfield Cable
- 400Hz Single Core Airfield Grounding Cable
- 400Hz Single Core with Control Wires
- 400Hz 3 core with Control Wires
- 400Hz 4 core with Control Wires
- 400Hz 7 core Airfield Cable
- 400Hz 7 core with Control Wires and Reinforcement
- 400Hz 7 core with Copper Tape Shield
- 400Hz 7 core LSZH AWA Airfield Cable
- 400Hz 7 core with Copper Wire Braid Shield
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|
| 1 | 35 | 11.5 | 430 |
| 1 | 50 | 12.6 | 665 |
| 1 | 70 | 14 | 910 |
| 1 | 120 | 23 | 1545 |
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|
| 1 | 16 | 10.7 | 216 |
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|
| 1 + 4 | 35 + 1 | 14.0 | 490 |
| 1 + 4 | 50 + 1 | 17.0 | 600 |
| 1 + 4 | 70 + 1 | 18.7 | 800 |
| 1 + 4 | 120 + 1 | 25.0 | 1400 |
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL CROSS SECTIONAL AREA SCREEN mm² | NO. CONTROL CORES | NOMINAL DIAMETER SINGLE CORE mm | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|---|---|---|
| 3 | 35 | 20 | 8 | 20.5 | 44.1 | 2790 |
| 3 | 70 | 25 | 8 | 22.2 | 47.8 | 3560 |
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NO. CONTROL CORES | NOMINAL DIAMETER SINGLE CORE mm | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|---|---|
| 4 | 35 | 4 | 13.7 | 33 | 2600 |
| 4 | 50 | 4 | 18.2 | 44 | 3900 |
| 4 | 70 | 4 | 21.2 | 51.3 | 4300 |
| 4 | 120 | 4 | 23.2 | 56 | 7400 |
| NUMBER CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL DIAMETER OF SINGLE CORE mm | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|---|
| 7 | 25 | 9.6 | 35 | 2800 |
| 7 | 35 | 10.6 | 39 | 3500 |
| 7 | 50 | 11.8 | 42.9 | 4000 |
| 7 | 70 | 13.6 | 49.2 | 5440 |
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL DIAMETER OF POWER CORE mm | NOMINAL DIAMETER OF CONTROL CORE mm | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|---|---|
| 7 + 6 | 25 + (3x1) | 9.6 | 1.8 | 38.3 | 2600 |
| 7 + 6 | 35 + (3x1) | 10.5 | 2.1 | 42 | 3100 |
| 7 + 6 | 25 + (4x1) | 9.6 | 1.8 | 42 | 2850 |
| 7 + 6 | 35 + (4x1) | 10.9 | 1.9 | 44 | 3050 |
| 7 + 6 | 50 + (4x1) | 11.8 | 2.1 | 51 | 4030 |
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL DIAMETER OF SINGLE CORE mm | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|---|
| 7 | 35 | 9.7 | 41.8 | 3450 |
| 7 | 50 | 11.8 | 47.8 | 4660 |
| 7 | 70 | 11.9 | 54.1 | 5930 |
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL DIAMETER OF SINGLE CORE mm | NOMINAL DIAMETER UNDER ARMOUR mm | NOMINAL DIAMETER OVER ARMOUR mm | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|---|---|---|
| 7 | 35 | 8.6 | 30 | 32.4 | 36.6 | 3355 |
| NUMBER OF CORES | NOMINAL CROSS SECTIONAL AREA mm² | NOMINAL DIAMETER OF SINGLE CORE mm | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km |
|---|---|---|---|---|
| 7 | 70 | 11.9 | 46.5 | 6430 |
Why Huadong Cable
Our vision is to become an internationally renowned brand in the field of cables; customer satisfaction, employee promotion, and corporate development are our service tenets; high standards, globalization, and building an international brand are our business philosophy.
About HuaDong
Henan Huadong Cable Co., Ltd. was founded in 1999 which is a joint-stock national high-tech enterprise integrating scientific research, industry and trade. Huadong Cable is deeply integrated into the "Belt and Road" construction and exports to more than 130 countries around the world, including Europe, South America, North America, the Middle East, Africa, Asia, and Oceania.
HuaDong Technology
Huadong Cable focuses on technology research and development which has 60 professional personnel with senior professional titles, and has more than 100 invention and utility model patents. Huadong has a team of experienced technical engineers to ensure the quality of cables.
Main Products
Our main products : marine cables, power cables, overhead cables, fireproof cables, low-smoke halogen-free cables, rubber cables, high temperature resistant cables, instrument and control cables, solar cables and other products.
ISO, SGS, BV CERTIFICATION; TECHNICAL PATENTS AND PRODUCT CERTIFICATION
TECHNICAL AND CLIENTS
Export Countries
Technical Patents
Annual Productivity
Employees